{"id":604,"date":"2011-12-01T08:31:32","date_gmt":"2011-12-01T08:31:32","guid":{"rendered":"https:\/\/fir3netwp.gmsrrpobkbd.com\/2011\/12\/01\/brocade-adx-port-profile\/"},"modified":"2021-07-24T18:24:01","modified_gmt":"2021-07-24T18:24:01","slug":"brocade-adx-port-profile","status":"publish","type":"post","link":"https:\/\/www.fir3net.com\/Loadbalancers\/Brocade\/brocade-adx-port-profile.html","title":{"rendered":"Brocade ADX – Port Profile"},"content":{"rendered":"
Port profiles provide the ability to configure custom settings for individual TCP\/UDP ports.<\/span> (config)# server port 8181 As UDP is stateless. At the point the ADX uses a UDP health-check if an ICMP unreachable is received the port is deemed down. However if no response is received from the server then the port is marked up. Depending on the configuration of the server without a port profile configured you may find that the servers are still showing as “Active”.<\/p>\n","protected":false},"excerpt":{"rendered":" Port profiles provide the ability to configure custom settings for individual TCP\/UDP ports. Any port that the ADX deems unknown, is in turn defined as UDP and will send any subsequent health-checks to the port via UDP. To use a unknown port a port profile must be configured. (config)# server port 8181(config-port-8181)# tcp keepalive use-master-state(config-port-8181)# … Read more<\/a><\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[14],"tags":[],"yoast_head":"\n
Any port that the ADX deems unknown, is in turn defined as UDP and will send any subsequent health-checks to the port via UDP.<\/span>
To use a unknown port a port profile must be configured.<\/span><\/p>\n
(config-port-8181)# tcp keepalive use-master-state
(config-port-8181)# no-fast-bringup
(config-port-8181)# tcp
(config-port-8181)# tcp 5
(config-port-8181)# udp<\/p>\nNote<\/strong><\/h4>\n
\n
Gotcha<\/strong><\/h4>\n