Netscreen – AC-VPN

AC-VPN Auto-connect VPN works with a hub and spoke setup. Once static VPNs have been configured between all the spokes and the hubs, AC-VPN and NHRP (Next Hop Routing Protocol) is configured on each spoke and the hub.When traffic is initiated between 2 spokes the traffic is passed via the hub while a dynamic tunnel … Read more

Netscreen – VPN Topologies

Back to Back VPNs Back to Back VPNs allow you to create a tunnel for each spoke to the hub. The hub will then have a policy to allow traffic from one tunnel to the next. You can either place each tunnel within its own zone and create a policy between each of the zones. … Read more

Netscreen `set arp always-on-dest` command

By default, Netscreen (ScreenOS versions 6.0.0 or below) will cache the source MAC address from the initial packet for a new session. It will then use this MAC address for the return traffic. This can cause problems with external routers running VRRP where traffic is sent using a Virtual IP but a physical MAC address … Read more

Netscreen – Overview of basic Traffic Shaping

There are 3 main types of traffic shaping on the Netscreen firewalls. Interface Based traffic shaping. Bandwidth allocated shaping in policies. Priority based traffic shapping in policies. Policy Based Policing Bandwidth: Traffic beyond this threshold is dropped at the ingress side of the security device.Guaranteed Bandwidth: Traffic below this threshold will be passed with highest … Read more

Netscreen – IGMP / PIM-SM

Internet Group Management Protocol (IGMP) is a communication protocol that multicasts messages and information among all member devices in an IP multicast group. Traffic is sent to a single MAC address but is forwarded out (via the local multicast router) to multiple hosts via multicast. It can be effectively used for gaming and showing online … Read more

ASA – How do I enable Netflow on an ASA?

NetFlow is a network protocol developed by Cisco Systems to run on a range of network devices for collecting IP traffic information. Previously only Cisco IOS routers and the Cisco 5580 ASA supported Netflow. But now with the introduction of Cisco ASA software 8.2, the complete ASA family now supports Netflow. There are 3 event … Read more

Netscreen – Redundant Interfaces – How to ??

  How to Configure an Redundant Interface Below shows you how to configure redundant interfaces on a Netscreen firewall. In the example below all traffic will be passed over eth1, and in event of the link failing traffic will be sent across eth2. ns5gt-> set interface redundant1 zone inside ns5gt-> set interface redundant1 ip 10.1.1.20/24 … Read more

Netscreen – Virtual Systems / VSYS

Virtual systems allow you to divide your Netscreen firewall into multiple logical firewalls (domains).Each VSYS (Virtual System) has 3 components which can be shared. Once shared they are available to other systems, virtual systems or root. The components are: Virtual Routers Zones Network Interfaces (Shared) How Virtual Systems work There are 3 ways in which … Read more

Netscreen – NSRP

HA Setups There are 3 main types of HA setup, they are, Active / Passive – All traffic passes the active node. In the event of failure the backup firewall is activated, and traffic flow is resumed. Active / Active – Both Firewalls share the network load. In the event of failure all traffic is … Read more

Check Point Backups

Oversimplified Executive Summary -A upgrade_export contains just Check Point configuration -A backup is an upgrade_export plus SPLAT OS configuration -A snapshot is a backup plus binary files, both Check Point and SPLAT OS -As a general rule of thumb, if your restoring on the same hardware a snapshot would be the easiest to use since … Read more

Netscreen – Rekeying a VPN / Clearing the SA`s

In order to rekey a Netscreen VPN you will need to either clear the phase 1 or phase 2 “keys” from the gateway. Phase 1 being the IKE cookies and phase 2 being the SA`s (Security Association). To see an overview of your VPN`s run the command, `get vpn` In order to find the current … Read more

Netscreen Attack Detection and Defense Overview

Below outlines Netcreens Attack Detection and Defense. This is by no means a full guide by acts as a general summary to the various terms and technologies. SCREEN Features legacy security protection, such as SYN, UDP and ICMP floods, Port scans and certain OS-specific DoS attacks. Deep Inspection Allows for inspection at the application layer … Read more

Netscreen – Basic Remote Access (Dial up) VPN

Below will show how to create a basic Remote Access VPN using Pre Shared Keys. This guide presumes that you already have the Netscren Remote VPN Client installed onto your local machine and was created using the following software versions : ScreenOS – 6.2.0r1.0 Netscren Remote VPN Client – 10.8.3 (Build 6) Below is an … Read more

Netscreen – Additional Site 2 Site VPN Options

VPN Monitoring This allows you to ping an IP address through the tunnel. In the event of the tunnel going down a SNMP trap will be generated. The settings can be found under “VPNs > AutoKey IKE > Edit > Advanced > VPN Monitor“. The “rekey” option will cause the Netscreen to continuously try and … Read more

Netscreen – Creating a route based VPN.

Below shows you how to create a route based vpn upon a Netscreen firewall using the firewalls gui interface. This tutorial was created using the ScreenOS version 6.2.0r1.0. The encryption domain for this guide will be, Local Gateway : 1.1.1.1 Local Endpoint : 10.1.1.25/24 Remote Gateway : 192.168.1.107 Remote Endpoint : 172.28.16.0/24 Create Tunnel Interface … Read more

Shell Script – Check Point Backup

This script will determine which operating system is running then backup the OS accordingly, once complete it will securely send it to the manager. The script is based on R65 and all backups will be sent to “/var/tmp/backups” on the manager. Each time the backup is run it will write a system log confirming if … Read more

Backup / Restore a Juniper NSM

This article will show you how to backup and restore your Juniper NSM. This article was written using NSM version 2008.2r1.Within NSM the HighAvailSvr contains processes that run in both HA and non-HA mode and handles database backups and a watchdog daemon to restart NSM processes in case of failure. Backup Even though you will … Read more

SmartView Monitor incorrectly shows status as Disconnected

Issue The SmartView Monitor shows the status of your gateway as “Disconnected”. It takes for ages before your gateway shows as “Connected. No AMON (Application Monitoring) packets (tcp/18192) are leaving the SmartCentre Server for the gateway. Solution This can be down to issues within the Database files for the SmartView Monitor. Below will show you … Read more

Check Point Solaris – Wrapper completed with error code 239

Issue On Solaris 8 or Solaris 9, installing Check Point package fails with either : /var/opt/cp_tmp/CPsuite-R65/install/request: /var/opt/cp_tmp/CPsuite-R65/install/request: cannot openpkgadd: ERROR: request script did not complete successfullyInstallation of <CPsuite-R65> failed. or /opt/CPInstLog/Wrapper_R65.elg contains[25/02 11:52:36]  Installing “Primary SmartCenter”[25/02 11:52:55]  Installing of “Primary SmartCenter” failed ![25/02 11:52:57]  Fail to install: Primary SmartCenter! See application usage format.[25/02 11:52:57]  Wrapper … Read more

Netscreen – Track IP

IP tracking allows you to track the connectivity of critical IP`s.This allows you to change your routing based on the connectivity of configured IP`s. There are 3 main points to Track IP :  If a Tracked IP becomes unreachable, the weight of the address is added to the overall failed address total. If the total … Read more

Want to become an IT Security expert?

Here is our hand-picked selection of the best courses you can find online:
Internet Security Deep Dive course
Complete Cyber Security Course – Hackers Exposed
CompTIA Security+ (SY0-601) Certification Complete course
and our recommended certification practice exams:
AlphaPrep Practice Tests - Free Trial